国产三线在线,亚洲久草在线视频,9久re热视频在线精品,久久久xxx

G120變頻器6SL3210-1PE31-1UL0西門(mén)子模塊
G120變頻器6SL3210-1PE31-1UL0西門(mén)子模塊
產(chǎn)品價(jià)格:¥13000(人民幣)
  • 規(guī)格:6SL3210-1PE31-1UL0
  • 發(fā)貨地:上海松江區(qū)
  • 品牌:
  • 最小起訂量:1臺(tái)
  • 誠(chéng)信商家
    會(huì)員級(jí)別:鉆石會(huì)員
    認(rèn)證類型:企業(yè)認(rèn)證
    企業(yè)證件:通過(guò)認(rèn)證

    商鋪名稱:上海斌勤電氣技術(shù)有限公司

    聯(lián)系人:康奎(先生)

    聯(lián)系手機(jī):

    固定電話:

    企業(yè)郵箱:192061030@qq.com

    聯(lián)系地址:上海市松江區(qū)三新北路1800弄(松江電子商務(wù)園區(qū))

    郵編:201501

    聯(lián)系我時(shí),請(qǐng)說(shuō)是在線纜網(wǎng)上看到的,謝謝!

    商品詳情
      商品描述
      價(jià)格說(shuō)明
      聯(lián)系我們;15900773813
      品牌
      西門(mén)子
      是否進(jìn)口
      加工定制
      產(chǎn)品認(rèn)證
      CE
      系列
      G120
      物料編碼
      1
      產(chǎn)地
      德國(guó)
      商品代碼
      85044084
      包裝尺寸
      67.00 x 210.00 x 237.00
      可售賣地
      全國(guó)
      型號(hào)
      6SL3210-1PE31-1UL0
      西門(mén)子 G120變頻器6SL3210-1PE31-1UL0功能及參數(shù)                                                 

      概述

      PM240?2 Power Modules – 0.55 kW to 250 kW (0.75 hp to 400 hp), IP20 degree of protection

      PM240?2 Power Modules, frame sizes FSA to FSG (with Control Unit and Operator Panel)

      The PM240?2 Power Modules are based on a new hardware platform. This permits an increase in power density as well as the application of innovative cooling concepts (push-through technology) with especially high requirements in terms of control cabinet cooling.

      Furthermore, the PM240-2 Power Module is also suitable for use in safety-oriented applications. In conjunction with a fail-safe Control Unit, the drive can be transformed into a Safety Integrated Drive (see section Control Units).

      The PM240?2 Power Modules in frame sizes FSA to FSF are available both with and without an integrated line filter class A of compact design for 200 V, 400 V and 690 V line voltages (except PM240?2 frame sizes FSD to FSF: 200 V). The PM240?2 Power Modules in frame size FSG are available with an integrated line filter Category C3 of compact design for 400 V and 690 V line voltages, also with integrated line filter Category C2 for a line voltage of 400 V. In addition, a DC link reactor is integrated in the PM240?2 Power Modules, frame sizes FSD to FSG, and therefore no line reactor is required.

      The PM240-2 Power Modules with integrated line filter class A are suitable for connection to TN supply systems. Power Modules without integrated line filter can be connected to grounded TN/TT systems and non-grounded IT systems.

      The PM240?2 Power Module has an integrated braking chopper. In generating mode, the excess energy of the DC link can be dissipated by means of an optional braking resistor.

      The permissible cable lengths between converter and motor are limited (for max. permissible cable lengths, see Integration). Longer cables can be used if output reactors are connected (see section Load-side power components).

      Push-through variant

      Example: PM240?2 Power Modules, degree of protection IP20, push-through variant, frame sizes FSD to FSF (with Control Unit and Operator Panel)

      The push-through variants in the frame sizes FSA to FSF allow the cooling fins of the Power Modules to be pushed through the rear panel of the control cabinet. Push-through variants should be used in applications where the amount of power loss generated inside the control cabinet itself must be minimized.

      Shield plates and shield connection kits are available for use in the wiring installation of Control Units and Power Modules to ensure that it complies with EMC guidelines.For more information, see Shield connection kits for Control Units and Power Modules in section Supplementary system components.

      PM250 Power Modules – 7.5 kW to 90 kW (10 hp to 125 hp), IP20 degree of protection

      PM250 Power Modules, frame sizes FSC to FSF

      PM250 Power Modules are suitable for a large number of applications in general mechanical engineering. Any braking energy is directly fed back into the line supply (four-quadrant applications – a braking chopper is not required).

      The PM250 Power Module features an absolutely unique technology – Efficient Infeed Technology. This feature provides the ability to feed energy back into the supply system in the generator mode (electronic braking) so that the energy is not converted into heat in a braking resistor. This saves space in the control cabinet. The time-consuming process of dimensioning the braking resistor and the expense of the extra wiring are eliminated. Furthermore, heat losses in the control cabinet are reduced.

      Further, the innovative circuit design reduces the line harmonics. There is no need to use an optional line reactor at the supply infeed. This saves space and costs for engineering and procurement.

      The permissible cable lengths between converter and motor are limited (for max. permissible cable lengths, see Integration). Longer cables can be used if output reactors are connected (see section Load-side power components).

      Frame sizes FSD to FSF of the PM250 Power Modules are available both with as well as without integrated line filter class A.

      For frame size FSC of the PM250 Power Module with an integrated line filter class A, an additional base filter of class B is available for achieving class B (see section Line-side components).

      The PM250 Power Module is also designed for safety-oriented applications. In conjunction with a fail-safe Control Unit, the drive can be transformed into a Safety Integrated Drive (see section Control Units).

      The PM250 Power Modules with integrated line filter class A are suitable for connection to TN supply systems. Power Modules without integrated line filter can be connected to grounded TN/TT systems and non-grounded IT systems.

      Note:

      Shield plates and shield connection kits are available for use in the wiring installation of Control Units and Power Modules to ensure that it complies with EMC guidelines.For more information, see Shield connection kits for Control Units and Power Modules in section Supplementary system components.