型號 |
名稱 |
MYJV |
煤礦用交聯聚乙烯絕緣聚氯乙烯護套電力電纜 |
MYJV22 |
煤礦用交聯聚乙烯絕緣鋼帶鎧裝聚氯乙烯護套電力電纜 |
MYJV32 |
煤礦用交聯聚乙烯絕緣細鋼絲鎧裝聚氯乙烯護套電力電纜 |
MYJV42 |
煤礦用交聯聚乙烯絕緣粗鋼絲鎧裝聚氯乙烯護套電力電纜 | | 規格尺寸:
型號 |
芯數 |
額定電壓(KV |
0.6/1 |
1.8/3 |
3.6/6、6/6 |
6/10、8.7/10 |
標稱截面(mm2) |
MYJV |
3 |
1.5~300 |
10~300 |
25~300 |
25~300 |
MYJV22 |
3 |
4~300 |
10~300 |
25~300 |
25~300 |
MYJV32 |
3 |
4~300 |
10~300 |
25~300 |
25~300 |
MYJV42 |
3 |
4~300 |
10~300 |
25~300 |
25~300 | 技術要求:
導體標稱截面(mm2) |
額定電壓(KV) |
0.6/1 |
1.8/3 |
3.6/6 |
6/6,6/10 |
8.7/10 |
絕緣標稱厚度(mm) |
1.5 |
0.7 |
- |
- |
- |
- |
2.5 |
0.7 |
- |
- |
- |
- |
4 |
0.7 |
- |
- |
- |
- |
6 |
0.7 |
- |
- |
- |
- |
10 |
0.7 |
2.0 |
2.5 |
- |
- |
16 |
0.7 |
2.0 |
2.5 |
3.4 |
- |
25 |
0.9 |
2.0 |
2.5 |
3.4 |
4.5 |
35 |
0.9 |
2.0 |
2.5 |
3.4 |
4.5 |
50 |
1.0 |
2.0 |
2.5 |
3.4 |
4.5 |
70 |
1.1 |
2.0 |
2.5 |
3.4 |
4.5 |
95 |
1.1 |
2.0 |
2.5 |
3.4 |
4.5 |
120 |
1.2 |
2.0 |
2.5 |
3.4 |
4.5 |
150 |
1.4 |
2.0 |
2.5 |
3.4 |
4.5 |
185 |
1.6 |
2.0 |
2.5 |
3.4 |
4.5 |
240 |
1.7 |
2.0 |
2.6 |
3.4 |
4.5 |
300 |
1.8 |
2.0 |
2.8 |
3.4 |
4.5 |
6kV~35kV 交聯聚乙烯絕緣電力電纜
|
交聯聚乙烯絕緣電力電纜是采用化學方法或物理方法,使聚乙烯分子由線型分子結構轉變為三維網狀結構,由熱塑性的聚乙烯變成熱固性的交聯聚乙烯,從而提高了聚乙烯的耐老化性能、機械性能和耐環境能力,并保持了優良的電氣性能。 交聯聚乙烯絕緣電力電纜導體的允許長期最高溫為900C,較低絕緣電纜、聚氯乙烯絕緣電纜和聚乙烯絕緣電纜高,且具有重量輕、結構簡單、使用方便、耐化學腐蝕和敷設不受落差限制等優點。 近年來,公司先后按IEC標準為全國城網改造、首都國際機場、北京西客站、中央電視臺、安順電廠、泰山核電站、二灘水電站、北侖電廠、伊敏電廠、揚州二電廠、上海地鐵、寶鋼集團、揚子石化等重點工程提供該系列產品,質量優良,獲得用戶一致好評。
.產品標準Standard 本產品按GB12706《額定電壓35V及以下銅芯、濾芯塑料絕緣電纜》標準生產,同時還可根據用戶需要按國際電工委員會推薦標準IEC、英國標準、德國標準及美國標準生產。 of《GB12706 or IEC、BS、DIN and ICEA upon request. 適用范圍Applications 本產品適用于工頻額定電壓3.6/6kv~26/35kv輸配電線路作配送電能子用。 · 工頻額定電壓U0/U為3.6/6kv~26/35kv。 3.6/6kv~26/35kv. · 電纜導體的最高允許工作溫度:90℃。 :90℃. · 短路時(最長時間不超過5s)電纜導體的最高溫度不超過2500C。
· 電纜敷設時環境溫度應不低于00C。 · 電纜彎曲半徑:三芯電纜不小于電纜外徑15倍;單芯電纜不小于電纜外徑20倍。 · 電纜的額定電壓應適合于電纜系統的運行狀況,用U0/U(Um)kv表示。 U0-電纜設計用的導體對地或金屬屏蔽之間的額定工頻電壓; U-電纜設計用的導體間的額定工頻電壓; Um-設備可承受的“最高系統電壓”的最大值。 ; . · 三相系統用電纜的U0值推薦如下表:
|
U kv |
U m kv |
U 0 * kv |
A 和 B 類系統 System categories A and B |
C 類系統 Systems categories C |
6 |
7.2 |
3.6 |
6 |
10 |
12 |
6 |
8.7 |
15 |
17.5 |
8.7 |
12 |
20 |
24 |
12 |
18 |
30 |
36 |
18 |
- |
35 |
40.5 |
21 |
26 | |
A類系統──該類系統任何一相導體與地和接地導體接觸時,能在1min內與系統分離 B類系統──該類系統僅包括單相接地故障短時運行的條件,接地故障時間應不超過1h, 但在任何情況下,最長不超過8h每年接地故障總持續時間不超過125h; C類系統──不屬于A類、B類的系統。 System categeory C──This category comprises all systems which do not fall into A and B 電纜的型號Type of cable |
型號 Type |
名稱 Designation |
適用范圍 Application |
YJV |
銅芯交聯聚乙烯絕緣氯乙烯護套電力電纜 Copper conductor,XLPE insulated and PVC sheathed power cable |
室內、隧道及電纜溝等場所,不能承受機械外力。單芯電纜不允許敷設在磁性管道中。 For laying indoors 、 intunnel or cable trench,unable to bear external mechan-icalforces.Single-core cable in magnetic duct is not permissible |
YJLY |
鋁芯交聯聚乙烯絕緣乙烯護套電力電纜 Aluminium conductor, XLPE insulated and PVC sheathed power cable |
YJY |
銅芯交聯聚乙烯絕緣氯乙烯護套電力電纜 Copper conductor ,XLPE insulated and PEsheathed power cable |
YJLY |
鋁芯交聯聚乙烯絕緣氯乙烯護套電力電纜 Alumimium conductor ,XLPE insulated and PEsheathed power cable |
YJV22 |
銅芯交聯聚乙烯絕緣鋼帶鎧裝聚氯乙烯護套電力電纜 Copper conductor ,XLPE insulated, steel tape armoured and PVC sheathed power cable |
室內、隧道、電纜溝內,或埋地敷設等,能承受一定機械外力,但不能承受大的拉力。 For laying indoors 、 in tunnel, cable trench, or direct in ground,able to bear external mechanicalforces, but unable to bear large pulling force 。 |
YJLV22 |
鋁芯交聯聚乙烯絕緣鋼帶鎧裝聚氯乙烯護套電力電纜 Aluminium conductor ,XLPE insulated ,steel tape armoured and PVC sheathed power cable |
YJV23 |
銅芯交聯聚乙烯絕緣鋼帶鎧裝聚氯乙烯護套電力電纜 Copper conductor ,XLPE insulated ,steel tape armoured and PVC sheathed power cable |
YJLV23 |
鋁芯交聯聚乙烯絕緣鋼帶鎧裝聚氯乙烯護套電力電纜 Aluminium conductor ,XLPE insulated ,steel tape armoured and PVC sheathed power cable |
YJV32 |
銅芯交聯聚乙烯絕緣細鋼絲鎧裝聚氯乙烯護套電力電纜 Copper conductor,XLPE insulated,steel wire armoured and PVC sheathed power cable |
室內、隧道、電纜溝、豎井或埋地敷設等,能承受機械外力和一定的拉力。 For laying indoors 、 in tunnel, cable french, well or direct in ground,able to bear external mechanical forces, and certain force 。 |
YJLV32 |
鋁芯交聯聚乙烯絕緣細鋼絲鎧裝聚氯乙烯護套電力電纜 Aluminium conductor ,XLPE insulated, steel wire armoured and PVC sheathed power cable |
YJV33 |
銅芯交聯聚乙烯絕緣細鋼絲鎧裝聚氯乙烯護套電力電纜 Copper conductor ,XLPE insulated ,steel wire armoured and PVC sheathed power cable |
YJLV33 |
鋁芯交聯聚乙烯絕緣鋼帶鎧裝聚氯乙烯護套電力電纜 Aluminium conductor ,XLPE insulated ,steel wire armoured and PVC sheathed power cable | |
生產范圍Production range of cable |
型號 Type |
芯數 Nomber of cores |
額定電壓 Rated Voltage kV |
3.6/6 |
6/6 6/10 |
8.7/10 8.7/15 |
12/20 |
18/20 18/30 |
21/35 |
26/35 |
導體標稱截面 Nominal cross-section of conductlr mm2 |
YJV YJLV YJY YJLY |
1 |
25-800 |
25-800 |
25-800 |
35-800 |
50-630 |
50-630 |
50-630 |
3 |
25-630 |
25-630 |
25-500 |
35-500 |
50-400 |
50-400 |
50-400 |
YJV22 YJLV22 YJY23 YJLY23 |
1 |
25-800 |
25-800 |
25-800 |
35-800 |
50-630 |
50-630 |
50-630 |
3 |
25-630 |
25-630 |
25-500 |
35-500 |
50-400 |
50-400 |
50-400 |
YJV32 YJLV32 YJY33 YJLY33 |
1 |
25-800 |
25-800 |
25-800 |
35-800 |
50-630 |
50-630 |
50-630 |
3 |
25-630 |
25-630 |
25-400 |
35-400 |
50-240 |
50-185 |
50-150 | | | |